This may be a really rookie error or oversight but I did have it working once and can't seem to do it again...
I have data coming in from a Labjack U12 at 20/sec times four channels - I have history set to 72000 and persistence set to 3800000 - This should, in theory be about two days?
I have several short time frame graphs using the same data and they all work fine - up to a time length of 600
My graph that is intended to show a full two days doesn't work - I can't get a display longer than a time length of about 3600 -
This makes me think I am missing something completely - if I set the time length to 200000 I get a display with two + days and dates shown in the graph window - at this sampling rate, I thought that the window (time) length would also be 3800000?
Is time window length independent of sampling rate?
I am clearly missing something about the process and previously (on a com-user where I was lucky to sample at 1/sec) got everything to work
What Have I failed to understand?
Thanks