  1. Ok, I have reinstalled the DAQFactoryExpress software and have upgraded it to the latest version ! When I now open te file I becom a Alert > C1033 Unable to load device driver LabJackN.dll check file path and maken sure manufacturer's drivers are installed. I've checked location of this file and I find it in C:\program files\DAQFActoryExpress\LabJackN.dll When I load the file it looks like it works (there is the alert but the sequence read is running), but it don't cound ! What's wrong now ?
  2. Thank you ! After the update it goes fine, but that's not easy to program ! Programming is not my stongest so this will be a puzzle for me. But that don't mather me, I will tri and it must be done ! Som little questions about the file : - there are 4 sequences but one (the Pin_Config_Reset sequence) of them is not in use (I think), where is this one used for ? - The sequence StartUp give's a Alert in the second row, I 've checked the path and that seems to be OK ! so what can there else be wrong ? - Can I find a "help dodument" .pdf or others what gives me a handheld to the program methode ? Is this an specifiek program languge ? or DAQFactory only ? thanks for so far !
  3. I think the new DAQFactory program is installed in a directory onder C:\Program Files\DAQFactory... You can try to copy the labjack.dll in this directory, that was the solution for me....
  4. Thank you for the try, but I can't load this file in DAQFactory 5 ! When I open it,DAQFactory com's with a little screen that says "Unable to load file, return to blank" ......... Is there an option to make a screen dump of it ? or make some screen dumps in a word document....
  5. I have a problem, I'm using the U3 with analoge signals now for a few months, with good results. The next step for me is to use the U3, to measure rpm's with a pulse sensor. The software i'm using is DAQFactory So I have tried many things, with no results until now. Witch settings do I have to make to measure (positive) pulses in a time period ? With a automatic reset from the counter/clock. When I set the U3 to counter mode, it counts the pulses but there is now time setting......... or an option for a reset from that counter after a time period...... When I set the U3 to clock mode (it dosn't matter which one), there is nothing happening !! DAQFactory dos'nt cound anything....... So there can be different problems (In mine opinion), I made a mistake by programming the U3 in combination with the DAQFactory software or the positive pulse is in clock mode not good !? > Edit The pulses are not the problem I've tested this in the "U3 test panel", end there it cound OK See this picture 1 My U3 settings > the first 2 ports are set to digital (For clock mode) Al other ports are set to analog See this picture 2 My DAQ factory settings > I have tried different clock settings but DAQFactory dus not show any result. I have checked the 2 clocks on the Labjack U3 settings in the pulldown menu on top of DAQFactory with a setting (I have tried different settings). By the way, the U3 dus not remember the settings with the puldown menu ! Anyone a answer ? (Sorry for my bad englisch)