Daggos
Members-
Posts
34 -
Joined
-
Last visited
Everything posted by Daggos
-
OK i have loaded runtime license onto the new device and still have same issue. only way i can get remote to work is delete the connection add a new connection then reset the connection. This works all data displays. then i save restart and nothing just invalid network packets. Using 18.1 build 2347
-
Pinging A Device From Daqfactory
Daggos replied to AzeoTech's topic in Networking: web, email, FTP etc.
LOL should have tried the old off and on again cheers mate. Works fine now- 16 replies
-
- ping
- networking
-
(and 1 more)
Tagged with:
-
Pinging A Device From Daqfactory
Daggos replied to AzeoTech's topic in Networking: web, email, FTP etc.
Still struggling. I have changed the line to global string pingIPs = {"192.168.141.50", "192.168.141.55", "192.168.141.94"} changed the single quotes to double. still getting 192.0.0.168 Thanks for your help- 16 replies
-
- ping
- networking
-
(and 1 more)
Tagged with:
-
Pinging A Device From Daqfactory
Daggos replied to AzeoTech's topic in Networking: web, email, FTP etc.
Thanks for that but the folder isn't the DAQ install folder i just created that folder for this script. the file is being created as intended but all that shows up is. Pinging 192.0.0.168 with 32 bytes of data: Request timed out. Request timed out. Request timed out. The problem is as you can see from my sequence that isn't the ip i have listed global pingIPs = {'192.168.141.50', '192.168.141.55', '192.168.141.94'}- 16 replies
-
- ping
- networking
-
(and 1 more)
Tagged with:
-
Pinging A Device From Daqfactory
Daggos replied to AzeoTech's topic in Networking: web, email, FTP etc.
Thanks for reply but these are my sequences below function checkPing(string ip, string path) system.ShellExecute("cmd","",'/C "ping ' + ip + " > " + path, "", "hide") delay(5) private h = file.Open(path,1,0,0,0) private string data = file.Read(h, file.GetLength(h)) file.Close(h) return(find(data,"TTL=",0) != -1) global pingIPs = {'192.168.141.50', '192.168.141.55', '192.168.141.94'} global pingState = fill(0, numrows(pingIPs)) while(1) try for (private i = 0, i < numrows(pingIPs), i++) pingState = checkPing(pingIps, "d:\DAQFACTORY\probe2") delay(0.1) endfor catch() ? strLastError delay(0.1) endcatch endwhile- 16 replies
-
- ping
- networking
-
(and 1 more)
Tagged with:
-
Pinging A Device From Daqfactory
Daggos replied to AzeoTech's topic in Networking: web, email, FTP etc.
Pinging 192.0.0.168 with 32 bytes of data: Request timed out. Request timed out. Request timed out. That's all i get in the file- 16 replies
-
- ping
- networking
-
(and 1 more)
Tagged with:
-
Hi I have been trying to test remote connections to my development DAQ on the same LAN with mixed results. If i add the remote connection details it will work with all channels lighting up but when i save and reopen it wont connect with error Invalid Network Packet. I have repeated this a few times. The remote connection is a trial pro i have 3 runtime licenses as well but are installed on other machines i want to test that the remotes work as i am hoping they do then buy more runtime licenses.
-
Thanks that works perfectly.
-
Hi I have found this script for displaying alarms in a table which is working perfectly but i would like to also filter the rows out by group as well. This is the sequence ======================================================== Global ALARM_DISPLAY_MANAGER_RUN_TIME private ALARM_DISPLAY_MANAGER_RUN_TIME_START Global Alm_Activos Global Alm_ActivosNum Global string AlmDateFormat = "%Y-%m-%d %H:%M:%S" Global NumRowsTodos_Alm = 0 private Alm_Activos_NSort private Alm_NActivos_NSort private string Todos_Alm private string strAlmIter private AlmIter private iter = 0 private i = 0 private k = 0 private n = 0 private string m private sort = 0 class Alm local string AlmName local AlmFired local AlmAck local AlmPriority local AlmTimeFired local string strAlmDesc local string strAlmTimeFired local string AlmEstado local string strAlmDescArray function CopyFrom(string obfrom) AlmName = obfrom Execute("AlmFired = Alarm."+AlmName+".Fired") Execute("AlmAck = Alarm."+AlmName+".Acked") Execute("AlmPriority = Alarm."+AlmName+".Priority") endfunction function ParseEstado() Execute("AlmTimeFired = Alarm."+AlmName+".TimeFired") Execute("strAlmDesc = Alarm."+AlmName+".strDescription") strAlmTimeFired = FormatDateTime(AlmDateFormat,AlmTimeFired) strAlmDescArray = Parse(strAlmDesc,-1,";") if(AlmFired) AlmEstado = "Alarming" else AlmEstado = "Reset" endif endfunction endclass Todos_Alm = Alarm.ListAll() while(1) try() ALARM_DISPLAY_MANAGER_RUN_TIME_START = systime() Alm_Activos_NSort.ClearHistory() Alm_NActivos_NSort.ClearHistory() if(NumRows(Todos_Alm)!=NumRowsTodos_Alm) Todos_Alm = Alarm.ListAll() endif NumRowsTodos_Alm = NumRows(Todos_Alm) iter = 0 while (iter<NumRowsTodos_Alm) strAlmIter = Todos_Alm[iter] AlmIter = new(Alm) AlmIter.CopyFrom(strAlmIter) if(AlmIter.AlmPriority==4 && (AlmIter.AlmFired || (!AlmIter.AlmFired && !AlmIter.AlmAck))) AlmIter.ParseEstado() if(AlmIter.AlmFired) Alm_Activos_NSort.Append(AlmIter) else Alm_NActivos_NSort.Append(AlmIter) endif endif iter=iter+1 endwhile sort = 0 if(sort == 1) n = NumRows(Alm_Activos_NSort) for( i = 1,i<n,i++) for (k = i, k > 0 && (Alm_Activos_NSort[k].AlmTimeFired > Alm_Activos_NSort[k-1].AlmTimeFired), k--) m = Alm_Activos_NSort[k-1] Alm_Activos_NSort[k-1]=Alm_Activos_NSort[k] Alm_Activos_NSort[k] = m endfor endfor n = NumRows(Alm_NActivos_NSort) for( i = 1,i<n,i++) for (k = i, k > 0 && (Alm_NActivos_NSort[k].AlmTimeFired > Alm_NActivos_NSort[k-1].AlmTimeFired), k--) m = Alm_NActivos_NSort[k-1] Alm_NActivos_NSort[k-1]=Alm_NActivos_NSort[k] Alm_NActivos_NSort[k] = m endfor endfor endif n = NumRows(Alm_NActivos_NSort) for( i = 0,i<n-1,i++) Alm_Activos_NSort.Append(Alm_NActivos_NSort) endfor Alm_Activos = Alm_Activos_NSort Alm_ActivosNum = NumRows(Alm_Activos) ALARM_DISPLAY_MANAGER_RUN_TIME = systime() - ALARM_DISPLAY_MANAGER_RUN_TIME_START catch() endcatch() delay(1) endwhile ================== Below are the table components Alm_Activos.strAlmTimeFired Alm_Activos.strAlmDescArray[0] Alm_Activos.strAlmDescArray[1] Alm_Activos.AlmEstado ======================== to display the group in separate column alarm description is as follows Pump Station 2; L1 ELR Alarm; or Pump Station 1; L1 ELR Alarm; ====================== So in the tables i want to only display group Pump Station 1 and a different table for Pump Station 2 Thanks for any help im hoping its a simple extra if statement